ACAC Power Module V2G Charging Module Bi-directional DC Charging Module
ACAC Power Module V2G Charging Module Bi-directional DC Charging Module
Voltage range: Rectifier and grid-connected inverter mode: 150 Vdc ~ 1000 Vdc
Off-grid inverter mode: 200 Vdc ~ 1000 Vdc
Current range: 0~73.3A (Current limiting point can be set)
Rated current: 22A @1000V
maximumoutput: 22kW
Stable pressure accuracy: < ±0.5%
Stable flow accuracy: ≤ ± 1% (20% to 100% output load)
load regulation: ≤±0.5%
Start the overshoot: ≤±3%
Grid adjustment rate: ± 0.1% (test range of 320V ~485V), rectification mode
Voltage ripple factor: 1% (300~1000V, 0 ~ 20 MHz), rectification mode
Cabinet routing and assembly suggestions:
1. Cabinet power wiring and communication line line separately to avoid spatial
coupling interference; pay special attention to DC CAN and AC CAN
communication bus should not be parallel with the power line.
2. The module AC line and DC line inside the system should be tied on both sides of the
module plug frame, and should not block the air outlet of the module.
As shown below
Leave Your Message:
Write your message here and send it to us